Specifications
| Lubricant Capacity | 125 ml |
|---|---|
| Rated service period | 1~12 ヶ月 |
| Ambient temperature range | -20~+60 ℃ |
| Maximum Generated Pressure | 5 bar |
| Lubricants | LGWM 2 (high load, wide temperature range) |
SKF SYSTEM 24 LAGD model comparison
Compare 18 models in the same series by specification.
| Model | Lubricant Capacity | Rated service period | Maximum Generated Pressure | Lubricants | Connection Thread | Ambient temperature range | Mass |
|---|---|---|---|---|---|---|---|
| LAGD 125/EM2 | 125 ml | 1~12 ヶ月 | 5 bar | LGEM 2 (high viscosity, solid lubricant) | — | -20~+60 ℃ | — |
| LAGD 125/FM100 | 125 ml | 1~12 ヶ月 | 5 bar | LFFM 100 (multi-purpose food grade oil, NSF H1) | — | -20~+60 ℃ | — |
| LAGD 125/FQ2 | 125 ml | 1~12 ヶ月 | 5 bar | LGFQ 2 (high load, wide temperature range, food grade, NSF H1) | — | -20~+60 ℃ | — |
| LAGD 125/FT220 | 125 ml | 1~12 ヶ月 | 5 bar | LFFT 220 (high-temperature food grade oil, NSF H1) | — | -20~+60 ℃ | — |
| LAGD 125/GB2 | 125 ml | 1~12 ヶ月 | 5 bar | LGGB 2 (biodegradable) | — | -20~+60 ℃ | — |
| LAGD 125/HB2 | 125 ml | 1~12 ヶ月 | 5 bar | LGHB 2 (high load, high temperature, high viscosity) | — | -20~+60 ℃ | — |
| LAGD 125/HMT68 | 125 ml | 1~12 ヶ月 | 5 bar | LHMT 68 (medium-temperature oil) | — | -20~+60 ℃ | — |
| LAGD 125/HQ2 | 125 ml | 1~12 ヶ月 | 5 bar | LGHQ 2 (high load, high temperature, high viscosity) | — | -20~+60 ℃ | — |
| LAGD 125/HT250 | 125 ml | 1~12 ヶ月 | 5 bar | LHHT 250 (high-temperature oil) | — | -20~+60 ℃ | — |
| LAGD 125/U | 125 ml | 1~12 ヶ月 | 5 bar | — | — | -20~+60 ℃ | — |
| LAGD 125/WA2 | 125 ml | 1~12 ヶ月 | 5 bar | LGWA 2 (high load, extreme pressure, wide temperature range) | R1/4 | -20~+60 ℃ | Approx. 200 g |
| LAGD 125/WM2 This product | 125 ml | 1~12 ヶ月 | 5 bar | LGWM 2 (high load, wide temperature range) | — | -20~+60 ℃ | — |
| LAGD 60/EM2 | 60 ml | 1~12 ヶ月 | 5 bar | LGEM 2 (high viscosity, solid lubricant) | — | -20~+60 ℃ | — |
| LAGD 60/HB2 | 60 ml | 1~12 ヶ月 | 5 bar | LGHB 2 (high load, high temperature, high viscosity) | — | -20~+60 ℃ | — |
| LAGD 60/HMT68 | 60 ml | 1~12 ヶ月 | 5 bar | LHMT 68 (medium-temperature oil) | — | -20~+60 ℃ | — |
| LAGD 60/HQ2 | 60 ml | 1~12 ヶ月 | 5 bar | LGHQ 2 (high load, high temperature, high viscosity) | — | -20~+60 ℃ | — |
| LAGD 60/U | 60 ml | 1~12 ヶ月 | 5 bar | — | — | -20~+60 ℃ | — |
| LAGD 60/WA2 | 60 ml | 1~12 ヶ月 | 5 bar | LGWA 2 (high load, extreme pressure, wide temperature range) | R1/4 | -20~+60 ℃ | Approx. 130 g |
How to choose Automatic lubrication devices
Points to check when selecting, with the values for this product (LAGD 125/WM2).
-
1. Select a lubricant suited to the application
This product: Lubricants LGWM 2 (high load, wide temperature range)Prefilled lubricants include high-temperature, high-load/extreme-pressure, NSF H1 registered food-machinery grades, and biodegradable types. Grease is generally used for bearings and oil for chains. Mixing with existing lubricants may reduce performance, so confirm the brand and thickener compatibility, and select an empty oil unit if you intend to use your own oil.
-
2. Determine capacity from required lubrication volume
This product: Lubricant Capacity 125 mlThe main capacities are 60 ml and 125 ml. Determine the capacity by multiplying the required lubrication volume for each lubrication point (such as the equipment manufacturer's recommended value) by the desired replacement interval. For the same discharge period, a larger capacity dispenses more lubricant per unit time, so check that it is neither too large nor too small for the size of the lubrication point.
-
3. Set the discharge period to match the replacement interval
This product: Rated service period 1~12 ヶ月The listed example allows the discharge period to be adjusted from 1 to 12 months. Matching it to the periodic inspection interval allows replacement work to be consolidated. Because gas-driven types change discharge speed with ambient temperature, periodically check the remaining lubricant in the transparent container to confirm it is decreasing as set.
-
4. Check generated pressure and piping conditions
This product: Maximum Generated Pressure 5 barThe maximum generated pressure of the listed product is 5 bar. Because the pressure is low, installing it at a distance with a hose may prevent discharge due to piping resistance. Direct mounting is the basic approach; when using stiff grease or long piping, check that the passage is not clogged and that back pressure is not high.
-
5. Match the thread standard of the lubrication port
If the mounting thread does not match the standard of the lubrication port (such as a grease nipple mounting hole), an adapter will be required. Confirm the thread standard and size on the equipment side in advance, and for oil use also check whether a check valve is included.
-
6. Confirm the operating environment and explosion-proofing requirements
This product: Ambient temperature range -20~+60 ℃The ambient temperature range affects discharge stability and lubricant performance, so compare it with the installation site temperature. In hazardous areas such as those with flammable gases, select an ATEX-certified product matching the zone classification (some products are also certified for Zone 0).
This guide was written by AI based on the listed products' documents and specification items.
Description
Gas cell driven, with a discharge period adjustable from 1 to 12 months. ATEX certified.
Features
- Wide temperature range
- Discharge period adjustable from 1 to 12 months
- ATEX certified
Applications
- Bearing housings
- Electric motors
FAQ
- Q. What is the lubricant capacity and rated service life of the SKF SYSTEM 24 LAGD 125/WM2?
- A. The lubricant capacity is 125 ml. The rated service life is 1 to 12 months, and the discharge period can be set within the range of 1 to 12 months.
- Q. What are the ambient temperature range and maximum generated pressure of the LAGD 125/WM2?
- A. The ambient temperature range is -20 to +60 ℃. The maximum generated pressure is 5 bar.
- Q. What type of lubricant is filled in the LAGD 125/WM2?
- A. It is LGWM 2 (high load, wide temperature range). It is filled with a high-load, wide-temperature-range grease.
- Q. What applications can the LAGD 125/WM2 be used for?
- A. It can be used for bearing housings and electric motors.
- Q. What is the drive method and certification of the LAGD 125/WM2?
- A. It is gas cell driven. It is ATEX certified.
Written by AI based on the content of the source documents.
Source documents
-
Catalog
SKF SYSTEM 24 - LAGDシリーズ ガス動作式シングルポイント自動給油/給脂装置
4 pages Open page 3
Found on: https://azuma-eg.com/catalogue/
More products from SKF
See all →-
Automatic lubrication devices
SKF SYSTEM 24 LAGD 60/WA2
Model: LAGD 60/WA2
Disposable single-point automatic lubricator driven by a gas cell. Holds 60 ml of grease with high load, extreme pressure, and wide temperature range properties.
SKF
-
Automatic lubrication devices
SKF SYSTEM 24 LAGD 125/WA2
Model: LAGD 125/WA2
A disposable, single-point automatic lubricator driven by a gas cell. Holds 125 ml of grease formulated for high load, extreme pressure, and a wide temperature range.
SKF
-
Automatic lubrication devices
SKF SYSTEM 24 LAGD 60/EM2
Model: LAGD 60/EM2
Automatic lubricator with 60 ml capacity. Filled with high-viscosity, solid lubricant grease.
SKF
-
Automatic lubrication devices
SKF SYSTEM 24 LAGD 125/EM2
Model: LAGD 125/EM2
Automatic lubricator with 125 ml capacity. Filled with high-viscosity, solid lubricating type grease.
SKF
-
Automatic lubrication devices
SKF SYSTEM 24 LAGD 125/GB2
Model: LAGD 125/GB2
Automatic lubricator with 125 ml capacity. Filled with biodegradable grease.
SKF
-
Automatic lubrication devices
SKF SYSTEM 24 LAGD 60/HB2
Model: LAGD 60/HB2
Automatic lubricator with 60 ml capacity. Filled with grease for high load, high temperature, and high viscosity applications.
SKF