Model TP1210 / STP1210 / タップスター / Japan Power Fastening Corporation (Official website)

コンクリートに埋め込み、インパクトドライバーで締め付けて固定するねじ固定式アンカー。M12の長尺タイプ。

Last verified: (date the content was verified against the source document)

Specifications

Overall length L 100 mm
Metric Thread Length 30 mm
Washer Outer Diameter 25 mm
Nut width across flats 19 mm
Anchor screw diameter 12.4 mm
Maximum thickness of workpiece 37 mm
Drill diameter (pilot hole diameter) 11.0 mm
Embedment depth 50 mm
Pull-Out Load 18 kN
Shear load 37 kN

タップスター model comparison

Compare 13 models in the same series by specification.

Model Anchor screw diameter Drill diameter (pilot hole diameter) Overall length L Embedment depth Pull-Out Load Shear load Maximum thickness of workpiece Metric Thread Length
TP1010 / STP1010 10.5 mm 9.5 mm 100 mm 45 mm 15 kN 22 kN 45 mm 25 mm
TP1060 / STP1060 10.5 mm 9.5 mm 60 mm 45 mm 15 kN 22 kN 5 mm 20 mm
TP1080 / STP1080 10.5 mm 9.5 mm 80 mm 45 mm 15 kN 22 kN 25 mm 25 mm
TP1210 / STP1210 This product 12.4 mm 11.0 mm 100 mm 50 mm 18 kN 37 kN 37 mm 30 mm
TP1212 12.4 mm 11.0 mm 120 mm 50 mm 18 kN 37 kN 47 mm 30 mm
TP1260 12.4 mm 11.0 mm 60 mm 40 mm 10 kN 24 kN 7 mm 20 mm
TP1270 / STP1270 12.4 mm 11.0 mm 70 mm 50 mm 18 kN 37 kN 7 mm 25 mm
TP1290 / STP1290 12.4 mm 11.0 mm 90 mm 50 mm 18 kN 37 kN 27 mm 30 mm
TP645 / STP645 6.5 mm 5.5 mm 45 mm 30 mm 6 kN 7 kN 5 mm 15 mm
TP660 / STP660 6.5 mm 5.5 mm 60 mm 30 mm 6 kN 7 kN 20 mm 20 mm
TP8110 8.5 mm 7.5 mm 110 mm 35 mm 9 kN 14 kN 70 mm 25 mm
TP850 / STP850 8.5 mm 7.5 mm 50 mm 35 mm 9 kN 14 kN 5 mm 20 mm
TP870 / STP870 8.5 mm 7.5 mm 70 mm 35 mm 9 kN 14 kN 20 mm 25 mm

How to choose Screw-in anchors

Points to check when selecting, with the values for this product (TP1210 / STP1210).

  1. 1. Select the bolt diameter to suit the attachment

    Determine the nominal diameter of the projecting metric thread (e.g., M6 to M12) according to the hole diameter and bracket specification of the attachment. The nominal diameter also changes the anchor thread diameter, pilot hole diameter, and nut width across flats for the tightening tool, so check these together.

  2. 2. Confirm the required pull-out load is met

    This product: Pull-Out Load 18 kN

    The listed products have pull-out loads of 6 to 18 kN. For hanging or ceiling installations, pull-out is the main load direction, so compare the value with the attachment weight and seismic loads including a safety factor. Also confirm the base strength and conditions under which the stated values were measured.

  3. 3. Check base type and embedment depth

    This product: Embedment depth 50 mm

    Holding capacity depends heavily on the base material and embedment depth (30 to 50 mm for listed products). Some examples show a maximum tensile load of about 1 kN in ALC and about 4 kN in lightweight block columns, which are much lower than in concrete, so always verify the compatible bases and the load values for each base.

  4. 4. Install with the specified pilot hole diameter

    This product: Drill diameter (pilot hole diameter) 11.0 mm

    The pilot hole diameter (5.5 to 11 mm for listed products) determines how far the threads bite into the base. A hole that is too large results in insufficient holding capacity, while one that is too small can prevent screw-in or cause damage. Use the drill diameter specified by the manufacturer, and note that even types without a pilot hole may require one depending on the base.

  5. 5. Choose a length that suits the attachment thickness

    This product: Maximum thickness of workpiece 37 mm

    Overall lengths range from 45 to 120 mm, and different lengths are available for the same nominal diameter. After securing the required embedment depth, select the length so that the attachment thickness (up to 5 to 70 mm) and the projecting thread length needed for the nut and washer are both accommodated.

  6. 6. Check shear load and material

    This product: Shear load 37 kN

    For applications with lateral forces, such as fixing brackets to walls, check the shear load (7 to 37 kN for listed products). For outdoor or humid locations, check whether steel-only or stainless steel versions are available and select a material suited to the corrosive environment.

This guide was written by AI based on the listed products' documents and specification items.

About Screw-in anchors and all products

Description

埋込深さ50mmで引抜18kN、せん断37kNの性能を持つ。取付物の最大厚みは37mm。鋼製とステンレス製があり、施工後も高さ調整が可能。

Features

  • インパクトドライバーで短時間に施工できる
  • 端部や仕上材が割れにくい
  • 施工後も高さ調整が可能
  • アンカーの取り外しが可能

Applications

  • 設備機器取付
  • 建築設備
  • 仮設工事

FAQ

Q. タップスター M12 x 100(TP1210 / STP1210)は、どのような部材に取り付けられますか?
A. コンクリートに埋め込み、インパクトドライバーで締め付けて固定するねじ固定式アンカーです。取付物の最大厚みは37mmです。
Q. タップスター M12 x 100(TP1210 / STP1210)の性能と取付時の下穴径を教えてください。
A. 埋込深さ50mmで引抜18kN、せん断37kNの性能を持ちます。ドリル径(下穴径)は11.0mmです。
Q. タップスター M12 x 100(TP1210 / STP1210)の用途と特長を教えてください。
A. 用途は設備機器取付、建築設備、仮設工事です。インパクトドライバーで短時間に施工でき、端部や仕上材が割れにくい特長があります。施工後も高さ調整が可能で、アンカーの取り外しもできます。
Q. タップスター M12 x 100(TP1210 / STP1210)には、どの材質がありますか?
A. 鋼製とステンレス製があります。

Written by AI based on the content of the source documents.

Source documents

More products from Japan Power Fastening Corporation