Specifications
| Overall length L | 90 mm |
|---|---|
| Metric Thread Length | 30 mm |
| Washer Outer Diameter | 25 mm |
| Nut width across flats | 19 mm |
| Anchor screw diameter | 12.4 mm |
| Maximum thickness of workpiece | 27 mm |
| Drill diameter (pilot hole diameter) | 11.0 mm |
| Embedment depth | 50 mm |
| Pull-Out Load | 18 kN |
| Shear load | 37 kN |
タップスター model comparison
Compare 13 models in the same series by specification.
| Model | Anchor screw diameter | Drill diameter (pilot hole diameter) | Overall length L | Embedment depth | Pull-Out Load | Shear load | Maximum thickness of workpiece | Metric Thread Length |
|---|---|---|---|---|---|---|---|---|
| TP1010 / STP1010 | 10.5 mm | 9.5 mm | 100 mm | 45 mm | 15 kN | 22 kN | 45 mm | 25 mm |
| TP1060 / STP1060 | 10.5 mm | 9.5 mm | 60 mm | 45 mm | 15 kN | 22 kN | 5 mm | 20 mm |
| TP1080 / STP1080 | 10.5 mm | 9.5 mm | 80 mm | 45 mm | 15 kN | 22 kN | 25 mm | 25 mm |
| TP1210 / STP1210 | 12.4 mm | 11.0 mm | 100 mm | 50 mm | 18 kN | 37 kN | 37 mm | 30 mm |
| TP1212 | 12.4 mm | 11.0 mm | 120 mm | 50 mm | 18 kN | 37 kN | 47 mm | 30 mm |
| TP1260 | 12.4 mm | 11.0 mm | 60 mm | 40 mm | 10 kN | 24 kN | 7 mm | 20 mm |
| TP1270 / STP1270 | 12.4 mm | 11.0 mm | 70 mm | 50 mm | 18 kN | 37 kN | 7 mm | 25 mm |
| TP1290 / STP1290 This product | 12.4 mm | 11.0 mm | 90 mm | 50 mm | 18 kN | 37 kN | 27 mm | 30 mm |
| TP645 / STP645 | 6.5 mm | 5.5 mm | 45 mm | 30 mm | 6 kN | 7 kN | 5 mm | 15 mm |
| TP660 / STP660 | 6.5 mm | 5.5 mm | 60 mm | 30 mm | 6 kN | 7 kN | 20 mm | 20 mm |
| TP8110 | 8.5 mm | 7.5 mm | 110 mm | 35 mm | 9 kN | 14 kN | 70 mm | 25 mm |
| TP850 / STP850 | 8.5 mm | 7.5 mm | 50 mm | 35 mm | 9 kN | 14 kN | 5 mm | 20 mm |
| TP870 / STP870 | 8.5 mm | 7.5 mm | 70 mm | 35 mm | 9 kN | 14 kN | 20 mm | 25 mm |
How to choose Screw-in anchors
Points to check when selecting, with the values for this product (TP1290 / STP1290).
-
1. Select the bolt diameter to suit the attachment
Determine the nominal diameter of the projecting metric thread (e.g., M6 to M12) according to the hole diameter and bracket specification of the attachment. The nominal diameter also changes the anchor thread diameter, pilot hole diameter, and nut width across flats for the tightening tool, so check these together.
-
2. Confirm the required pull-out load is met
This product: Pull-Out Load 18 kNThe listed products have pull-out loads of 6 to 18 kN. For hanging or ceiling installations, pull-out is the main load direction, so compare the value with the attachment weight and seismic loads including a safety factor. Also confirm the base strength and conditions under which the stated values were measured.
-
3. Check base type and embedment depth
This product: Embedment depth 50 mmHolding capacity depends heavily on the base material and embedment depth (30 to 50 mm for listed products). Some examples show a maximum tensile load of about 1 kN in ALC and about 4 kN in lightweight block columns, which are much lower than in concrete, so always verify the compatible bases and the load values for each base.
-
4. Install with the specified pilot hole diameter
This product: Drill diameter (pilot hole diameter) 11.0 mmThe pilot hole diameter (5.5 to 11 mm for listed products) determines how far the threads bite into the base. A hole that is too large results in insufficient holding capacity, while one that is too small can prevent screw-in or cause damage. Use the drill diameter specified by the manufacturer, and note that even types without a pilot hole may require one depending on the base.
-
5. Choose a length that suits the attachment thickness
This product: Maximum thickness of workpiece 27 mmOverall lengths range from 45 to 120 mm, and different lengths are available for the same nominal diameter. After securing the required embedment depth, select the length so that the attachment thickness (up to 5 to 70 mm) and the projecting thread length needed for the nut and washer are both accommodated.
-
6. Check shear load and material
This product: Shear load 37 kNFor applications with lateral forces, such as fixing brackets to walls, check the shear load (7 to 37 kN for listed products). For outdoor or humid locations, check whether steel-only or stainless steel versions are available and select a material suited to the corrosive environment.
This guide was written by AI based on the listed products' documents and specification items.
Description
Provides 18 kN pull-out and 37 kN shear performance at an embedment depth of 50 mm. Maximum fixture thickness is 27 mm. Available in steel and stainless steel. Height adjustment is possible after installation.
Features
- Can be installed in a short time with an impact driver
- Edges and finishing materials are less prone to cracking
- Height adjustment is possible after installation
- Anchor can be removed
Applications
- Equipment installation
- Building services
- Temporary construction
FAQ
- Q. What concrete applications can Tapstar M12 x 90 (TP1290 / STP1290) be used for?
- A. It can be used for equipment installation, building services, and temporary construction. It is a screw-type anchor embedded in concrete and fixed by tightening with an impact driver.
- Q. What are the drill hole diameter (pilot hole diameter) and embedment depth for installing Tapstar M12 x 90 (TP1290 / STP1290)?
- A. The drill hole diameter (pilot hole diameter) is 11.0 mm and the embedment depth is 50 mm.
- Q. What are the load-bearing performance and applicable fixture thickness of Tapstar M12 x 90 (TP1290 / STP1290)?
- A. At an embedment depth of 50 mm, it provides a pull-out load of 18 kN and a shear load of 37 kN. The maximum fixture thickness is 27 mm.
- Q. Is Tapstar M12 x 90 (TP1290 / STP1290) available in different materials?
- A. Yes, it is available in steel and stainless steel.
- Q. Can Tapstar M12 x 90 (TP1290 / STP1290) be height-adjusted or removed after installation?
- A. Yes, height adjustment is possible after installation. The anchor can also be removed.
Written by AI based on the content of the source documents.
Source documents
-
Catalog
TAP STAR タップスター コンクリート用ねじ固定式アンカー
2 pages Found on: https://www.jpf-net.co.jp/ebook.html
More products from Japan Power Fastening Corporation
See all →-
Screw-in anchors
Bolt Screw 8×45
Model: 8×45
Multi-purpose screw-in anchor that can be installed directly into ALC, plywood and wood without pilot holes. Short model with a bolt length of 15 mm.
Japan Power Fastening Corporation
-
Screw-in anchors
Bolt Screw 8×60
Model: 8×60
Multi-purpose screw-in anchor that can be installed directly into ALC, plywood and wood without pre-drilling. Standard model with a bolt length of 20 mm. Stainless steel version available.
Japan Power Fastening Corporation
-
Screw-in anchors
Bolt Screw 8×90
Model: 8×90
Multi-purpose screw-in fixing anchor for direct installation into ALC, plywood and wood without pilot holes. Long model with 30 mm bolt length. Stainless steel version available.
Japan Power Fastening Corporation
-
Screw-in anchors
Tapstar M6 x 45
Model: TP645 / STP645
Screw-type anchor installed by drilling a pilot hole in concrete, inserting the anchor, and tightening with an impact driver to secure it. Short-length type in M6.
Japan Power Fastening Corporation
-
Screw-in anchors
Tapstar M6 x 60
Model: TP660 / STP660
Screw-type anchor embedded in concrete and fixed by tightening with an impact driver. Standard length type in M6.
Japan Power Fastening Corporation
-
Screw-in anchors
Tapstar M8 x 50
Model: TP850 / STP850
Screw-type anchor embedded in concrete and fixed by tightening with an impact driver. Short type in M8.
Japan Power Fastening Corporation