Tapster M12 x120
Model TP1212 / タップスター / Japan Power Fastening Corporation (Official website)
Screw-type anchor embedded in concrete and fixed by tightening with an impact driver. Long type in M12, steel only.
Last verified: (date the content was verified against the source document)
Specifications
| Overall length L | 120 mm |
|---|---|
| Metric Thread Length | 30 mm |
| Washer Outer Diameter | 25 mm |
| Nut width across flats | 19 mm |
| Anchor screw diameter | 12.4 mm |
| Maximum thickness of workpiece | 47 mm |
| Drill diameter (pilot hole diameter) | 11.0 mm |
| Embedment depth | 50 mm |
| Pull-Out Load | 18 kN |
| Shear load | 37 kN |
タップスター model comparison
Compare 13 models in the same series by specification.
| Model | Anchor screw diameter | Drill diameter (pilot hole diameter) | Overall length L | Embedment depth | Pull-Out Load | Shear load | Maximum thickness of workpiece | Metric Thread Length |
|---|---|---|---|---|---|---|---|---|
| TP1010 / STP1010 | 10.5 mm | 9.5 mm | 100 mm | 45 mm | 15 kN | 22 kN | 45 mm | 25 mm |
| TP1060 / STP1060 | 10.5 mm | 9.5 mm | 60 mm | 45 mm | 15 kN | 22 kN | 5 mm | 20 mm |
| TP1080 / STP1080 | 10.5 mm | 9.5 mm | 80 mm | 45 mm | 15 kN | 22 kN | 25 mm | 25 mm |
| TP1210 / STP1210 | 12.4 mm | 11.0 mm | 100 mm | 50 mm | 18 kN | 37 kN | 37 mm | 30 mm |
| TP1212 This product | 12.4 mm | 11.0 mm | 120 mm | 50 mm | 18 kN | 37 kN | 47 mm | 30 mm |
| TP1260 | 12.4 mm | 11.0 mm | 60 mm | 40 mm | 10 kN | 24 kN | 7 mm | 20 mm |
| TP1270 / STP1270 | 12.4 mm | 11.0 mm | 70 mm | 50 mm | 18 kN | 37 kN | 7 mm | 25 mm |
| TP1290 / STP1290 | 12.4 mm | 11.0 mm | 90 mm | 50 mm | 18 kN | 37 kN | 27 mm | 30 mm |
| TP645 / STP645 | 6.5 mm | 5.5 mm | 45 mm | 30 mm | 6 kN | 7 kN | 5 mm | 15 mm |
| TP660 / STP660 | 6.5 mm | 5.5 mm | 60 mm | 30 mm | 6 kN | 7 kN | 20 mm | 20 mm |
| TP8110 | 8.5 mm | 7.5 mm | 110 mm | 35 mm | 9 kN | 14 kN | 70 mm | 25 mm |
| TP850 / STP850 | 8.5 mm | 7.5 mm | 50 mm | 35 mm | 9 kN | 14 kN | 5 mm | 20 mm |
| TP870 / STP870 | 8.5 mm | 7.5 mm | 70 mm | 35 mm | 9 kN | 14 kN | 20 mm | 25 mm |
How to choose Screw-in anchors
Points to check when selecting, with the values for this product (TP1212).
-
1. Select the bolt diameter to suit the attachment
Determine the nominal diameter of the projecting metric thread (e.g., M6 to M12) according to the hole diameter and bracket specification of the attachment. The nominal diameter also changes the anchor thread diameter, pilot hole diameter, and nut width across flats for the tightening tool, so check these together.
-
2. Confirm the required pull-out load is met
This product: Pull-Out Load 18 kNThe listed products have pull-out loads of 6 to 18 kN. For hanging or ceiling installations, pull-out is the main load direction, so compare the value with the attachment weight and seismic loads including a safety factor. Also confirm the base strength and conditions under which the stated values were measured.
-
3. Check base type and embedment depth
This product: Embedment depth 50 mmHolding capacity depends heavily on the base material and embedment depth (30 to 50 mm for listed products). Some examples show a maximum tensile load of about 1 kN in ALC and about 4 kN in lightweight block columns, which are much lower than in concrete, so always verify the compatible bases and the load values for each base.
-
4. Install with the specified pilot hole diameter
This product: Drill diameter (pilot hole diameter) 11.0 mmThe pilot hole diameter (5.5 to 11 mm for listed products) determines how far the threads bite into the base. A hole that is too large results in insufficient holding capacity, while one that is too small can prevent screw-in or cause damage. Use the drill diameter specified by the manufacturer, and note that even types without a pilot hole may require one depending on the base.
-
5. Choose a length that suits the attachment thickness
This product: Maximum thickness of workpiece 47 mmOverall lengths range from 45 to 120 mm, and different lengths are available for the same nominal diameter. After securing the required embedment depth, select the length so that the attachment thickness (up to 5 to 70 mm) and the projecting thread length needed for the nut and washer are both accommodated.
-
6. Check shear load and material
This product: Shear load 37 kNFor applications with lateral forces, such as fixing brackets to walls, check the shear load (7 to 37 kN for listed products). For outdoor or humid locations, check whether steel-only or stainless steel versions are available and select a material suited to the corrosive environment.
This guide was written by AI based on the listed products' documents and specification items.
Description
Provides pull-out capacity of 18 kN and shear capacity of 37 kN at an embedment depth of 50 mm. Maximum thickness of attached object is 47 mm. Height can be adjusted after installation.
Features
- Can be installed in a short time with an impact driver
- Edges and finishing materials are less prone to cracking
- Height can be adjusted after installation
- Anchor can be removed
Applications
- Equipment installation
- Building services
- Temporary construction
FAQ
- Q. What type of concrete can the Tapster M12 x120 (TP1212) be used to install into?
- A. It is a screw-type anchor embedded in concrete and fixed by tightening with an impact driver. It is used for equipment installation, building services, and temporary construction.
- Q. What is the installation method for TP1212, and can it be adjusted after installation?
- A. It is installed by tightening with an impact driver and can be installed in a short time. Height can be adjusted after installation. The anchor can also be removed.
- Q. What are the dimensions of TP1212 and the maximum thickness of attached object it can accommodate?
- A. Overall length L is 120 mm, metric thread length is 30 mm, washer outer diameter is 25 mm, and nut width across flats is 19 mm. Maximum thickness of attached object is 47 mm.
- Q. What is the embedment depth of TP1212, and what are its pull-out and shear loads?
- A. Embedment depth is 50 mm, pull-out load is 18 kN, and shear load is 37 kN. Drill diameter (pilot hole diameter) is 11.0 mm.
Written by AI based on the content of the source documents.
Source documents
-
Catalog
TAP STAR タップスター コンクリート用ねじ固定式アンカー
2 pages Found on: https://www.jpf-net.co.jp/ebook.html
More products from Japan Power Fastening Corporation
See all →-
Screw-in anchors
Bolt Screw 8×45
Model: 8×45
Multi-purpose screw-in anchor that can be installed directly into ALC, plywood and wood without pilot holes. Short model with a bolt length of 15 mm.
Japan Power Fastening Corporation
-
Screw-in anchors
Bolt Screw 8×60
Model: 8×60
Multi-purpose screw-in anchor that can be installed directly into ALC, plywood and wood without pre-drilling. Standard model with a bolt length of 20 mm. Stainless steel version available.
Japan Power Fastening Corporation
-
Screw-in anchors
Bolt Screw 8×90
Model: 8×90
Multi-purpose screw-in fixing anchor for direct installation into ALC, plywood and wood without pilot holes. Long model with 30 mm bolt length. Stainless steel version available.
Japan Power Fastening Corporation
-
Screw-in anchors
Tapstar M6 x 45
Model: TP645 / STP645
Screw-type anchor installed by drilling a pilot hole in concrete, inserting the anchor, and tightening with an impact driver to secure it. Short-length type in M6.
Japan Power Fastening Corporation
-
Screw-in anchors
Tapstar M6 x 60
Model: TP660 / STP660
Screw-type anchor embedded in concrete and fixed by tightening with an impact driver. Standard length type in M6.
Japan Power Fastening Corporation
-
Screw-in anchors
Tapstar M8 x 50
Model: TP850 / STP850
Screw-type anchor embedded in concrete and fixed by tightening with an impact driver. Short type in M8.
Japan Power Fastening Corporation