Compact Transmitter CSA-507C
Model CSA-507C / CSA-507 / Minebea Mitsumi Inc. (Official website)
Compact, lightweight, and simple low-cost transmitter.
Last verified: (date the content was verified against the source document)
Specifications
| Bridge power supply | 2.5, 5, 10 VDC |
|---|---|
| Input range | 0.5 to 3 mV/V |
| Output voltage | ±10 (non-isolated) V |
| Frequency response range | 1, 10, 100, 1k Hz |
| Power Consumption | 5 VA |
| Mass | 0.65 kg |
How to choose Transmitter
Points to check when selecting, with the values for this product (CSA-507C).
-
1. Select an input range that matches the sensor output
This product: Input range 0.5 to 3 mV/VThe rated output (mV/V) of the connected sensor must fall within the input range of the transmitter. Listed products offer a wide input range of 0.3 to 500 mV/V. For sensors with a small rated output, selecting a model with a lower input range limit makes it easier to secure resolution.
-
2. Output format suited to the receiving side
This product: Output voltage ±10 (non-isolated) VCheck whether the output is voltage (such as ±10 V) or current (such as 4 to 20 mA) against the input specifications of the PLC or recorder. In environments with long cable runs and high noise, current output is advantageous. For digital output models, also confirm the baud rate (921.6 kbps in the listed example) and the number of units that can be connected in parallel.
-
3. Match bridge excitation voltage to the sensor
This product: Bridge power supply 2.5, 5, 10 VDCStrain gauge sensors have a permissible excitation voltage, and exceeding it causes heat generation and drift. Compare the recommended excitation voltage in the sensor specifications with the bridge power supply of the transmitter. If cable runs are long, also check whether remote sensing is available to compensate for voltage drop.
-
4. Response bandwidth suited to the rate of change of the measured quantity
This product: Frequency response range 1, 10, 100, 1k HzFor measuring fast phenomena such as impact loads or torque fluctuations, a model with a wide frequency response range is required. Listed examples include high-response types with a response frequency of 25 kHz and digital types with 2 kHz. For static measurements, check whether a low-pass filter can be set to suppress noise.
-
5. Nonlinearity relative to required accuracy
Nonlinearity is the deviation of output relative to input, expressed as a percentage of full scale, and listed products range from 0.01 to 0.05% F.S. The overall system accuracy is determined by the sum of the errors of the sensor and the transmitter. Determine the required grade together with the accuracy of the sensor side.
-
6. Match power supply and installation form to the equipment
Match whether the power supply is AC or DC 24 V to the power configuration of the control panel. For integration into equipment or multi-channel use, board-type or multi-channel models save space. Check the external dimensions, mass (0.05 to 2.5 kg) and power consumption, and confirm that they fit the available installation space and power capacity.
This guide was written by AI based on the listed products' documents and specification items.
Description
Non-isolated output method. Auto-zero function is sold separately.
Features
- Compact and lightweight
- Low cost
Applications
- General measurement
FAQ
- Q. What bridge excitation voltage and input range are suitable for the CSA-507C?
- A. Bridge excitation is 2.5, 5, or 10 VDC, and the input range is 0.5 to 3 mV/V.
- Q. What is the output method and output voltage of the CSA-507C?
- A. The output method is non-isolated, and the output voltage is ±10 V. The auto-zero function is sold separately.
- Q. What are the frequency response range, power consumption, and mass of the CSA-507C?
- A. The frequency response range is 1, 10, 100, and 1k Hz, power consumption is 5 VA, and mass is 0.65 kg.
Written by AI based on the content of the source documents.
Source documents
-
Catalog
製品ガイダンス 計測・計装用各種センサー・機器類
24 pages Found on: https://azuma-eg.com/catalogue/
More products from Minebea Mitsumi Inc.
See all →-
Transmitter
High-Response Transmitter CSA-522B
Model: CSA-522B
A high-response DC amplifier used for measuring load, pressure, torque and other quantities.
Minebea Mitsumi Inc.
-
Transmitter
Transmitter CSA-503C
Model: CSA-503C
Transmitter with built-in remote sensing circuit. Auto-zero function is sold separately.
Minebea Mitsumi Inc.
-
Transmitter
Printed Circuit Board Type Transmitter CSA-521
Model: CSA-521
Compact, lightweight, low-cost printed circuit board type transmitter.
Minebea Mitsumi Inc.
-
Transmitter
Board-Type Transmitter CSA-528
Model: CSA-528
A board-type transmitter powered by DC24V that saves space when used with multiple channels.
Minebea Mitsumi Inc.
-
Transmitter
Printed Circuit Board Type Transmitter CSA-504S
Model: CSA-504S
A printed circuit board type transmitter available in two types: 1ch (CSA-504S-1B) and 4ch (CSA-504SB).
Minebea Mitsumi Inc.
-
Transmitter
Torque Converter Dedicated Transmitter OPT-563B
Model: OPT-563B
Transmitter for optical transmission type torque converters. Stores calibration data for four units and allows switching between them.
Minebea Mitsumi Inc.