Transmitter CSA-591/CSA-592
Model CSA-591/CSA-592 / CSA-591 / Minebea Mitsumi Inc. (Official website)
Transmitter with analog voltage output. Equipped with auto-zero function.
Last verified: (date the content was verified against the source document)
Specifications
| Bridge power supply | DC8 V ±0.3 V, within 30 mA |
|---|---|
| Output voltage | ±10 V |
| Power supply voltage | DC24 (DC18 to DC36) V |
| Mass | 0.5 kg |
How to choose Transmitter
Points to check when selecting, with the values for this product (CSA-591/CSA-592).
-
1. Select an input range that matches the sensor output
The rated output (mV/V) of the connected sensor must fall within the input range of the transmitter. Listed products offer a wide input range of 0.3 to 500 mV/V. For sensors with a small rated output, selecting a model with a lower input range limit makes it easier to secure resolution.
-
2. Output format suited to the receiving side
This product: Output voltage ±10 VCheck whether the output is voltage (such as ±10 V) or current (such as 4 to 20 mA) against the input specifications of the PLC or recorder. In environments with long cable runs and high noise, current output is advantageous. For digital output models, also confirm the baud rate (921.6 kbps in the listed example) and the number of units that can be connected in parallel.
-
3. Match bridge excitation voltage to the sensor
This product: Bridge power supply DC8 V ±0.3 V, within 30 mAStrain gauge sensors have a permissible excitation voltage, and exceeding it causes heat generation and drift. Compare the recommended excitation voltage in the sensor specifications with the bridge power supply of the transmitter. If cable runs are long, also check whether remote sensing is available to compensate for voltage drop.
-
4. Response bandwidth suited to the rate of change of the measured quantity
For measuring fast phenomena such as impact loads or torque fluctuations, a model with a wide frequency response range is required. Listed examples include high-response types with a response frequency of 25 kHz and digital types with 2 kHz. For static measurements, check whether a low-pass filter can be set to suppress noise.
-
5. Nonlinearity relative to required accuracy
Nonlinearity is the deviation of output relative to input, expressed as a percentage of full scale, and listed products range from 0.01 to 0.05% F.S. The overall system accuracy is determined by the sum of the errors of the sensor and the transmitter. Determine the required grade together with the accuracy of the sensor side.
-
6. Match power supply and installation form to the equipment
This product: Power supply voltage DC24 (DC18 to DC36) VMatch whether the power supply is AC or DC 24 V to the power configuration of the control panel. For integration into equipment or multi-channel use, board-type or multi-channel models save space. Check the external dimensions, mass (0.05 to 2.5 kg) and power consumption, and confirm that they fit the available installation space and power capacity.
This guide was written by AI based on the listed products' documents and specification items.
Description
CSA-591 supports the auto-zero function, which is sold separately.
Features
- Analog voltage output
- Auto-zero function
Applications
- Tie bar measurement
FAQ
- Q. What are the bridge power supply and output voltage specifications for CSA-591/CSA-592?
- A. The bridge power supply is DC 8 V ±0.3 V, 30 mA or less. The output voltage is ±10 V.
- Q. What are the power supply voltage and mass of CSA-591/CSA-592?
- A. The power supply voltage is DC 24 V (DC 18 to DC 36 V). The mass is 0.5 kg.
- Q. What are the applications and features of CSA-591/CSA-592?
- A. The application is tie bar measurement. It is a transmitter with analog voltage output and an auto-zero function.
- Q. How is the auto-zero function of CSA-591 used?
- A. CSA-591 supports the auto-zero function, which is sold separately.
Written by AI based on the content of the source documents.
Source documents
-
Catalog
製品ガイダンス 計測・計装用各種センサー・機器類
24 pages Found on: https://azuma-eg.com/catalogue/
More products from Minebea Mitsumi Inc.
See all →-
Transmitter
High-Response Transmitter CSA-522B
Model: CSA-522B
A high-response DC amplifier used for measuring load, pressure, torque and other quantities.
Minebea Mitsumi Inc.
-
Transmitter
Transmitter CSA-503C
Model: CSA-503C
Transmitter with built-in remote sensing circuit. Auto-zero function is sold separately.
Minebea Mitsumi Inc.
-
Transmitter
Compact Transmitter CSA-507C
Model: CSA-507C
Compact, lightweight, and simple low-cost transmitter.
Minebea Mitsumi Inc.
-
Transmitter
Printed Circuit Board Type Transmitter CSA-521
Model: CSA-521
Compact, lightweight, low-cost printed circuit board type transmitter.
Minebea Mitsumi Inc.
-
Transmitter
Board-Type Transmitter CSA-528
Model: CSA-528
A board-type transmitter powered by DC24V that saves space when used with multiple channels.
Minebea Mitsumi Inc.
-
Transmitter
Printed Circuit Board Type Transmitter CSA-504S
Model: CSA-504S
A printed circuit board type transmitter available in two types: 1ch (CSA-504S-1B) and 4ch (CSA-504SB).
Minebea Mitsumi Inc.