Digital Transmitter CSD-592
Model CSD-592 / Minebea Mitsumi Inc. (Official website)
High-response, low-cost digital transmitter. Supports control and operation management.
Last verified: (date the content was verified against the source document)
Specifications
| Bridge power supply | DC5 V ±0.05 V, within 15 mA |
|---|---|
| Frequency response range | 2 kHz |
| Power supply voltage | DC12 V |
| Current Consumption | Approx. 150 mA |
| Mass | 0.25 kg |
How to choose Transmitter
Points to check when selecting, with the values for this product (CSD-592).
-
1. Select an input range that matches the sensor output
The rated output (mV/V) of the connected sensor must fall within the input range of the transmitter. Listed products offer a wide input range of 0.3 to 500 mV/V. For sensors with a small rated output, selecting a model with a lower input range limit makes it easier to secure resolution.
-
2. Output format suited to the receiving side
Check whether the output is voltage (such as ±10 V) or current (such as 4 to 20 mA) against the input specifications of the PLC or recorder. In environments with long cable runs and high noise, current output is advantageous. For digital output models, also confirm the baud rate (921.6 kbps in the listed example) and the number of units that can be connected in parallel.
-
3. Match bridge excitation voltage to the sensor
This product: Bridge power supply DC5 V ±0.05 V, within 15 mAStrain gauge sensors have a permissible excitation voltage, and exceeding it causes heat generation and drift. Compare the recommended excitation voltage in the sensor specifications with the bridge power supply of the transmitter. If cable runs are long, also check whether remote sensing is available to compensate for voltage drop.
-
4. Response bandwidth suited to the rate of change of the measured quantity
This product: Frequency response range 2 kHzFor measuring fast phenomena such as impact loads or torque fluctuations, a model with a wide frequency response range is required. Listed examples include high-response types with a response frequency of 25 kHz and digital types with 2 kHz. For static measurements, check whether a low-pass filter can be set to suppress noise.
-
5. Nonlinearity relative to required accuracy
Nonlinearity is the deviation of output relative to input, expressed as a percentage of full scale, and listed products range from 0.01 to 0.05% F.S. The overall system accuracy is determined by the sum of the errors of the sensor and the transmitter. Determine the required grade together with the accuracy of the sensor side.
-
6. Match power supply and installation form to the equipment
This product: Power supply voltage DC12 VMatch whether the power supply is AC or DC 24 V to the power configuration of the control panel. For integration into equipment or multi-channel use, board-type or multi-channel models save space. Check the external dimensions, mass (0.05 to 2.5 kg) and power consumption, and confirm that they fit the available installation space and power capacity.
This guide was written by AI based on the listed products' documents and specification items.
Description
Equipped with RS-422 output as standard, used for tie bar gauge measurement.
Features
- High response 2kHz
- RS-422 output
Applications
- Tie bar measurement
- Operation management
FAQ
- Q. What kind of measurement can the RS-422 output of the CSD-592 be used for?
- A. The RS-422 output is equipped as standard and is used for tie bar gauge measurement. Applications include tie bar measurement and operation management.
- Q. What are the frequency response range and power supply specifications of the CSD-592?
- A. The frequency response range is 2 kHz. The power supply voltage is DC 12 V and the current consumption is approximately 150 mA. The bridge power supply is DC 5 V ±0.05 V, within 15 mA.
- Q. What is the mass of the CSD-592?
- A. The mass is 0.25 kg.
Written by AI based on the content of the source documents.
Source documents
-
Catalog
製品ガイダンス 計測・計装用各種センサー・機器類
24 pages Found on: https://azuma-eg.com/catalogue/
More products from Minebea Mitsumi Inc.
See all →-
Transmitter
High-Response Transmitter CSA-522B
Model: CSA-522B
A high-response DC amplifier used for measuring load, pressure, torque and other quantities.
Minebea Mitsumi Inc.
-
Transmitter
Transmitter CSA-503C
Model: CSA-503C
Transmitter with built-in remote sensing circuit. Auto-zero function is sold separately.
Minebea Mitsumi Inc.
-
Transmitter
Compact Transmitter CSA-507C
Model: CSA-507C
Compact, lightweight, and simple low-cost transmitter.
Minebea Mitsumi Inc.
-
Transmitter
Printed Circuit Board Type Transmitter CSA-521
Model: CSA-521
Compact, lightweight, low-cost printed circuit board type transmitter.
Minebea Mitsumi Inc.
-
Transmitter
Board-Type Transmitter CSA-528
Model: CSA-528
A board-type transmitter powered by DC24V that saves space when used with multiple channels.
Minebea Mitsumi Inc.
-
Transmitter
Printed Circuit Board Type Transmitter CSA-504S
Model: CSA-504S
A printed circuit board type transmitter available in two types: 1ch (CSA-504S-1B) and 4ch (CSA-504SB).
Minebea Mitsumi Inc.