Model TKSA 51 / TKSA / SKF (Official website) / Listed on page 85 of the document

A shaft alignment system operated via an app on a tablet or smartphone.

Last verified: (date the content was verified against the source document)

Shaft Alignment System TKSA 51 on page 85 of SKF "SKFメンテナンス製品と潤滑製品"
Source: SKF「SKFメンテナンス製品と潤滑製品」page 85
A reduced image of the relevant page is quoted from the document. Copyright belongs to SKF.Request removal

Specifications

Minimum Shaft Rotation Angle 40 度
Measurement Distance 7 cm – 5 m
Measurement Error <1% ±10 μm
Measurement Unit Mass 190 g

TKSA model comparison

Compare 7 models in the same series by specification.

Model Measurement Distance Measurement Error Minimum Shaft Rotation Angle Continuous operating time Protection Rating (IP) Measurement Unit Mass Total mass (incl. case)
TKSA 11 0 – 185 mm (between brackets) Less than 2% / 10 μm 180 ° Max. 18 時間 Measuring unit IP54 (probe IP67) 155 g 2.1 kg
TKSA 31 7 cm – 4 m <0,5% ±5 μm 40 ° — — — —
TKSA 41 7 cm – 4 m — 90 ° Max. 16 時間 — 220 g —
TKSA 51 This product 7 cm – 5 m <1% ±10 μm 40 度 — — 190 g —
TKSA 71 4 cm – 10 m <1% ±10 μm 40 ° — — 130 g 3.9 kg
TKSA 71 / TKSA 71/PRO 10 m — — — IP67 — —
TKSA 71/PRO 4 cm – 10 m <1% ±10 μm 40 ° — — 130 g 12.5 kg

How to choose Shaft alignment devices

Points to check when selecting, with the values for this product (TKSA 51).

  1. 1. Measuring distance to suit shaft spacing

    This product: Measurement Distance 7 cm – 5 m

    Measurement is not possible if the distance between the measuring units exceeds the instrument's measuring range. Estimate the mounting spacing of the two units across the coupling, and for long spacer shafts or large machines choose a model with ample margin under its upper limit.

  2. 2. Measurement error against required accuracy

    This product: Measurement Error <1% ±10 μm

    Measurement error is often stated as a combination of a percentage and a fixed value (μm), and the error band increases as the measured value grows. For equipment with small permissible misalignment, such as high-speed rotating machines, confirm that the error is sufficiently small relative to the allowable value.

  3. 3. Checking the required rotation angle

    This product: Minimum Shaft Rotation Angle 40 度

    Among the listed products, the minimum shaft rotation angle required for measurement varies from 40° to 180°. For equipment where it is difficult to rotate the shaft half a turn due to piping or surrounding structures, a model that measures with a smaller rotation angle is suitable.

  4. 4. Shaft diameter and coupling height

    Confirm the shaft diameter that can be fitted with standard brackets and the coupling height that standard rods can clear (55 mm in the listed example). For large-diameter shafts or large couplings, check whether extension chains (up to 320 mm) or extension rods (up to 175 mm) are available.

  5. 5. Sensor type and operating device

    The type of detection sensor and the wireless communication method affect measurement stability and how the instrument is operated. Choose between a dedicated display unit and an app on a personal smartphone or tablet, and check whether bringing such devices to the site is restricted.

  6. 6. Site environment and portability

    For outdoor sites or locations with water or dust, check the protection rating and operating temperature range. Total mass including the case ranges from 2.1 to 12.5 kg, and trolley-case models that include brackets are heavier, so select based on how the instrument will be transported.

This guide was written by AI based on the listed products' documents and specification items.

About Shaft alignment devices and all products

Description

Supports horizontal and vertical shaft alignment and soft foot correction, and features disturbance compensation.

Features

  • 3D live image display
  • Compact and lightweight

Applications

  • Alignment of motors, pumps, fans, etc.

FAQ

Q. What types of machines can the TKSA 51 be used to align shafts on?
A. It can be used for alignment of motors, pumps, fans, etc. It supports horizontal and vertical shaft alignment and soft foot correction.
Q. What are the measurement unit mass, measurement distance, and measurement error of the TKSA 51?
A. The measurement unit mass is 190 g. The measurement distance is 7 cm – 5 m. The measurement error is <1% ±10 μm.
Q. How is the TKSA 51 operated and how are measurement results checked?
A. It is operated via an app on a tablet or smartphone. Measurement results can be checked with the 3D live image display.