Catalog Searcher
Categories

Double-Acting Rotary Seal R10-FS

Model R10-FS / ロータリーシール / SKF (Official website) / Listed on page 54 of the document

A rotary seal for harsh operating conditions that features the R10-F shape and uses a special-profile energizer instead of an O-ring.

Last verified: (date the content was verified against the source document)

Double-Acting Rotary Seal R10-FS on page 54 of SKF "切削加工シール製品ラインアップ"
Source: SKF「切削加工シール製品ラインアップ」page 54
A reduced image of the relevant page is quoted from the document. Copyright belongs to SKF.Request removal

Specifications

Operating Temperature Range -30~+200 °C
Maximum Sliding Speed 0.4 m/s
Maximum Operating Pressure 350 bar

ロータリーシール model comparison

Compare 25 models in the same series by specification.

Model Maximum Sliding Speed Maximum Operating Pressure Operating Temperature Range
R01-AF2 0.5 m/s 15 bar —
R02-P 0.2 m/s — 0~+80 °C
R02-R 0.2 m/s — -50~+200 °C
R03-P 0.2 m/s 400 bar -40~+100 °C
R03-R 0.2 m/s 250 bar -50~+200 °C
R04-A 0.2 m/s 160 bar -50~+110 °C
R05-A 0.2 m/s 160 bar -50~+110 °C
R06-P 25 m/s — -50~+110 °C
R06-R 25 m/s — -50~+200 °C
R07-P 25 m/s — -50~+110 °C
R07-R 25 m/s — -50~+200 °C
R08-A — — -60~+200 °C
R08-P 2.5 m/s — -50~+110 °C
R08-R 7.5 m/s — -60~+200 °C
R09-F 0.4 m/s 350 bar -20~+200 °C
R09-FS 0.4 m/s 350 bar -30~+200 °C
R10-F 0.4 m/s 350 bar -20~+200 °C
R10-FS This product 0.4 m/s 350 bar -30~+200 °C
R11-F 20 m/s 5 bar -200~+260 °C
R19-F 2 m/s 150 bar -200~+260 °C
R19-FX 2 m/s 150 bar -200~+260 °C
R30-A 0.5 m/s — -25~+200 °C
TX 11 m/s — -30~+150 °C
TY 11 m/s — -30~+150 °C
TZ 11 m/s — -30~+150 °C

How to choose Rotary Seals

Points to check when selecting, with the values for this product (R10-FS).

  1. 1. Select a size that matches the shaft diameter

    Select seals to match the diameter of the shaft on which they are installed. Listed products cover a shaft diameter range of 5 to 1000 mm, and the applicable range differs by type. Shaft tolerance and surface roughness also affect sealing performance and wear, so check the recommended groove dimensions together with the shaft diameter.

  2. 2. Confirm the peripheral speed is within the limit

    This product: Maximum Sliding Speed 0.4 m/s

    Sliding speed is evaluated as the peripheral speed calculated from shaft diameter and rotational speed. The listed upper limits range widely from 0.2 to 25 m/s, and higher speeds make lips and slide rings more prone to wear from frictional heat. Choose a product with a margin above the actual peripheral speed, for example from PTFE spring-loaded types recommended for low friction and high speed.

  3. 3. Match the pressure rating and single- or double-acting design

    This product: Maximum Operating Pressure 350 bar

    The maximum operating pressure of listed products is 5 to 400 bar. Springless lip seals are mainly intended for grease retention and foreign matter exclusion and are not suitable for high pressure. For rotary joints and rotary pivots subject to high pressure or pressure from both sides, consider double-acting PTFE seals combined with O-rings.

  4. 4. Select materials suited to temperature and fluid

    Rubber-based materials such as NBR offer excellent elasticity, while PTFE offers superior chemical resistance, heat resistance and low friction. PTFE is often selected for chemical and pharmaceutical applications and high-temperature environments. Check that the O-ring material of the energizer is compatible with both the operating temperature range and the fluid used.

  5. 5. Check the cross-section dimensions for the groove

    Cross-section dimensions range from 0.85 to 10.5 mm and must match the width and depth of the housing groove. When replacing existing equipment, match the cross-section dimensions as well as the shaft diameter, and confirm that the squeeze is appropriate.

  6. 6. Determine whether a split design is required

    Split designs that can be divided into two halves are available for plummer blocks, allowing replacement without removing the shaft and reducing maintenance effort. When using a one-piece type, confirm during the design stage whether it can be inserted from the shaft end and whether chamfers or tooling are provided to avoid damaging the lip.

This guide was written by AI based on the listed products' documents and specification items.

About Rotary Seals and all products

Description

Designed for harsh operating conditions and special housings.

Features

  • Special energizer
  • Suitable for harsh conditions

Applications

  • Machine tools

FAQ

Q. Under what conditions can the R10-FS be used? Please provide the operating temperature range and maximum operating pressure.
A. The operating temperature range is -30 to +200 °C, and the maximum operating pressure is 350 bar. It is designed for harsh operating conditions and special housings.
Q. What is the maximum sliding speed of the R10-FS?
A. The maximum sliding speed is 0.4 m/s.
Q. How does the R10-FS differ from the R10-F?
A. It has the R10-F shape and uses a special-profile energizer instead of an O-ring. It is a rotary seal for harsh conditions.
Q. What applications is the R10-FS suited for?
A. Its application is machine tools. It is a rotary seal suitable for harsh conditions.

Written by AI based on the content of the source documents.

Source documents

Similar products (other manufacturers)

Rotary Seals products, ordered by similarity of specifications and applications.

More products from SKF