Medical Coil Spring Tip Rounding Process

Spring net (Official website) / Listed on page 16 of the document

Laser processing service that rounds the tips of fine-wire coil springs and straight materials. Applicable wire diameters range from approximately 0.08Φ to 3Φ.

Last verified: (date the content was verified against the source document)

Medical Coil Spring Tip Rounding Process on page 16 of Spring net "スプリングネット 製品カタログ(ばね類)"
Source: Spring net「スプリングネット 製品カタログ(ばね類)」page 16
A reduced image of the relevant page is quoted from the document. Copyright belongs to Spring net.Request removal

Specifications

Wire diameter d 0.08~3 Φ
Unit price for medical coil springs (10 pcs or more) 2,000 円(税抜)
Delivery time (medical coil springs) Shipped 15 days after order

How to choose Springs

Points to check when selecting, with the values for this product (Medical Coil Spring Tip Rounding Process).

  1. 1. Select the Spring Rate from the Required Force

    The spring rate k is the load required to deflect the spring by 1 mm. Multiply it by the deflection at installation and at operation to confirm that the required force can be obtained. Listed products range widely from 0.007 to 9.91 N/mm, and a margin should be allowed for variation, including the spring rate tolerance (for example, ±10%).

  2. 2. Keep Within the Maximum Load and Deflection Limits

    Using the spring beyond its maximum load or maximum deflection causes set (permanent deformation) or breakage. Confirm that the load at the maximum point of the operating stroke is within the maximum load, and for compression springs, that the solid height is not reached.

  3. 3. Installation Space, Outside Diameter, and Free Length

    Check that the outside diameter fits the hole or housing, and that the inside diameter does not interfere with the shaft it passes over (applicable shaft diameter). The free length is the length under no load; the difference from the installed length is the initial deflection. Because the coil diameter changes under load, allow sufficient clearance.

  4. 4. Select a Material Suited to the Operating Environment

    Piano wire SWP-A has high strength but is prone to rust, and many versions are supplied with rust-preventive oil treatment. For humid environments or environments subject to washing, stainless steel such as SUS304-WPB is a candidate. For strongly corrosive environments such as seawater, titanium is a candidate.

  5. 5. Extension Springs: Initial Tension and Hook Shape

    Close-wound extension springs have initial tension, the load required before the spring begins to extend. For applications requiring movement with a small force, check the initial tension value. Also check that the hook shape, such as reverse loop, 90-degree, or 180-degree, matches how the mating part is engaged.

  6. 6. Torsion Springs: Angle and Arm Direction

    For torsion springs, check the torque at the operating angle (torsion spring rate × angle) and the arm length. The winding direction should match the direction of twist, and it is common to use the spring in the direction that winds it up. For free-size products, also specify the bending direction.

This guide was written by AI based on the listed products' documents and specification items.

About Springs and all products

Description

Tips are rounded using a laser processing welding machine, preventing snagging and scratches caused by cut surfaces. Compatible with medical ultra-small coils and straight materials, it can also be applied to hook sections of compression, extension, and torsion springs.

Features

  • Rounded tips are less likely to damage mating components
  • Faster and cleaner than grinding
  • Compatible with ultra-fine 0.08Φ wire

Applications

  • Medical ultra-small coils
  • Tip processing of straight materials
  • Hook sections of compression, extension, and torsion springs

FAQ

Q. What is the wire diameter range supported for the Medical Coil Spring Tip Rounding Process?
A. Wire diameter d is supported from 0.08Φ to 3Φ. Ultra-fine 0.08Φ wire is also supported.
Q. What are the effects of rounding the tips in the Medical Coil Spring Tip Rounding Process?
A. Tips are rounded using a laser processing welding machine, which prevents snagging and scratches caused by cut surfaces. The rounded tips are less likely to damage mating components.
Q. Which components can the Medical Coil Spring Tip Rounding Process be applied to?
A. It can be applied to medical ultra-small coils, tip processing of straight materials, and hook sections of compression, extension, and torsion springs.

Written by AI based on the content of the source documents.