Catalog Searcher
Categories

SKF SYSTEM 24 Wired Single-Point Automatic Lubricator TLSD Series

TLSD 有線式 / SKF (Official website) / Listed on page 172 of the document

A wired automatic lubricator that is powered from the machine control panel, integrates with PLCs, and lubricates only while the machine is running.

Last verified: (date the content was verified against the source document)

SKF SYSTEM 24 Wired Single-Point Automatic Lubricator TLSD Series on page 172 of SKF "SKFメンテナンス製品と潤滑製品"
Source: SKF「SKFメンテナンス製品と潤滑製品」page 172
A reduced image of the relevant page is quoted from the document. Copyright belongs to SKF.Request removal

Specifications

Lubricant Capacity 125 / 250 ml
Discharge period 1–12 ヶ月
Minimum Discharge Volume 0,3 / 0,7 ml/日
Maximum Discharge Volume 4,1 / 8,3 ml/日
Ambient temperature range -20 – 50 °C
Maximum Operating Pressure 5 bar
Protection Rating (IP) IP 41
Power source 7 – 35 (max 1,5A) V
Weight 355 g
Cable length 550 mm
Connection Thread G1/4

How to choose Single-point automatic lubricator

Points to check when selecting, with the values for this product (SKF SYSTEM 24 Wired Single-Point Automatic Lubricator TLSD Series).

  1. 1. Select capacity and period to match discharge requirements

    This product: Lubricant Capacity 125 / 250 ml

    Match the required daily lubricant quantity to a combination of lubricant capacity (60 to 250 ml in listed models) and discharge period (1 to 24 months). The actual lubricant quantity is the capacity divided by the period, so calculate backward from the bearing's requirement and align the replacement interval with the maintenance plan to simplify management.

  2. 2. Check the available range of discharge periods

    This product: Discharge period 1–12 ヶ月

    Gas-driven models can be set from 1 to 12 months, and some electromechanical models can be set up to 24 months. Confirm whether the setting is dial-type and tool-free, and whether it can be changed or stopped midway, to ensure it can accommodate seasonal or operating condition changes.

  3. 3. Choose the drive method based on environment and control

    Gas-driven types are suitable where power cannot be supplied or in hazardous areas, and some are ATEX certified. Electromechanical or wired types are better where temperature changes are large, where lubrication is needed only while the machine is running, or where PLC monitoring is required.

  4. 4. Confirm discharge pressure is sufficient for pipe length

    This product: Maximum Operating Pressure 5 bar

    The maximum operating pressure of listed models is 5 to 30 bar. When lubricating from a distant position through piping, pressure loss increases, so a higher-pressure model is required. The maximum supply length varies greatly by product, up to 300 m for grease and up to 5 m for oil, so always verify it against the specifications.

  5. 5. Match the thread standard of the lubrication point

    This product: Connection Thread G1/4

    Check that the connection thread matches the standard of the lubrication point (grease nipple mounting hole). If it does not match, an adapter is required, and a longer mounting assembly can cause loosening or breakage due to vibration, so verify the mounting space as well.

  6. 6. Verify ambient temperature range and lubricant compatibility

    This product: Ambient temperature range -20 – 50 °C

    Confirm that the ambient temperature range covers the minimum and maximum temperatures at the installation site. Also confirm that the filled lubricant type suits the bearing conditions and, for food machinery, that it is NSF H1 food grade. For outdoor or washdown environments, also check the protection rating (IP code).

This guide was written by AI based on the listed products' documents and specification items.

About Single-point automatic lubricator and all products

Description

Operates on external power and supplies lubricant only while the machine is running. The output signal can be used by the machine's PLC. Status is displayed by LEDs visible from four sides, and cartridges of 125 ml and 250 ml are supported. Rated IP41 protection class.

Features

  • Lubrication only while the machine is running
  • Control and monitoring via PLC connection
  • External power supply
  • Discharge rate unaffected by temperature
  • Status indication by red, yellow, and green LEDs

Applications

  • Critical machinery requiring very high reliability and additional monitoring
  • Industrial machinery
  • Elevators
  • Compressors

FAQ

Q. In what types of machinery can the SKF SYSTEM 24 Wired Single-Point Automatic Lubricator TLSD Series be used?
A. It is used in critical machinery requiring very high reliability and additional monitoring, industrial machinery, elevators, and compressors. It is powered from the machine control panel and can be integrated with a PLC.
Q. When does the TLSD Series lubricate the machine, and how does it interface with the PLC?
A. It lubricates only while the machine is running. The output signal can be used by the machine's PLC.
Q. What are the lubricant capacity, discharge period, and discharge volume range of the TLSD Series?
A. Lubricant capacity is 125 / 250 ml. Discharge period is 1–12 months. Minimum discharge volume is 0.3 / 0.7 ml/day, and maximum discharge volume is 4.1 / 8.3 ml/day.
Q. What are the power supply, ambient temperature range, maximum operating pressure, and protection class of the TLSD Series?
A. Power supply is 7 – 35 (max. 1.5 A) V. Ambient temperature range is -20 – 50 °C, maximum operating pressure is 5 bar, and protection class is IP 41.
Q. What are the dimensions, connection specifications, and status display method of the TLSD Series?
A. Weight is 355 g, cable length is 550 mm, and connection thread is G1/4. Status is shown by red, yellow, and green LEDs, which are visible from four sides.

Written by AI based on the content of the source documents.